Magnetron Information (2,45 GHz) Magnetron 2450 MHz HISTEC Logo
zur industriellen Mikrowellenerzeugung
 
µ-CONTROLLER-SYSTEMS / HARD- & SOFTWARE-DESIGN
POWER-SUPPLIES FROM MILLIWATTS TO KILOWATTS
 
  produkte > schaltnetzteile > magnetron-info
 
Wasser /Luft -gekühlt

Magnetron 2450 MHz - Technische Daten
Mikrowellen - Magnetron 2.45 GHz (1.0 - 3.0 kW)

PDF - Magnetrons-2450-MHz

Magnetron image
Type HF-
Ausgangs-
Leistung
Frequenz Kühlung* Luft/Wasser Heiz- Strom Heiz- Spg Anoden Strom Anoden Spitzen Strom Anoden Spg. Magnet
EM = Elektro-Magnet
PM = Permanent-Magnet
  HF-
Output-
Power
frequency cooling* Air/Water filament current filament voltage   anode current anode peak current anode voltage Magnet
EM = Electro-Magnet
PM = Permanent-Magnet
        If Uf Ia Iap Ua  
2M244 1.010 W 2.455 MHz Air 10,0 A 3,15 V 320 mA 1.300 mA 4,35 kV PM / Ferrite
2M247 1.050 W 2.455 MHz Air/ Water 13,5 A 3,40 V 350 mA 1.400 mA 4,35 kV PM / Ferrite
2M248 1.020 W 2.460 MHz Air 10,0 A 3,15 V 330 mA 4,35 kV PM / Ferrite
NL10305 1.050 W 2.455 MHz Air 13,5 A 3,40 V 350 mA 1.400 mA 4,35 kV PM / Ferrite
NL10246 1.050 W 2.460 MHz Air 10,5 A 3,15 V 330 mA 1.500 mA 4,40 kV PM / Ferrite
                   
YJ1540 1.250 W 2.455 MHz Air/Water 14,0 A 4,40 V 400 mA 1.600 mA 4,50 kV PM / Ferrite
2M137 1.250 W 2.455 MHz Air 14,0 A 4,40 V 400 mA 1.600 mA 4,50 kV PM / Ferrite
                   
2M259 2.030 W 2.455 MHz Air 20,0 A 4,60 V 725 mA 2.100 mA 4,00 kV PM / Ferrite
2M259WJ 2.030 W 2.455 MHz Water 20,0 A 4,60 V 725 mA 2.100 mA 4,00 kV PM / Ferrite
NL10250 2.000 W 2.455 MHz Air/Water 19,0 A 4,60 V 725 mA 2.100 mA 4,00 kV PM / Ferrite
                   
2M265 3.000 W 2.455 MHz Air 22,0 A 4,00 V 840 mA 3.100 mA 5,10 kV PM / Ferrite
2M265WJ 3.000 W 2.455 MHz Water 22,0 A 4,00 V 840 mA 3.100 mA 5,10 kV PM / Ferrite
2M266 3.000 W 2.455 MHz Air 22,0 A 4,00 V 840 mA 3.100 mA 5,10 kV PM / Samarium-Cobalt
2M266WJ 3.000 W 2.455 MHz Water 22,0 A 4,00 V 840 mA 3.100 mA 5,10 kV PM / Samarium-Cobalt
NL10230 3.000 W 2.455 MHz Water 16,0 A 4,60 V 900 mA 2.650 mA 5,40 kV PM / Ferrite

* F.A. Forced Air    - Luft
  W.C. Water Cooling - Wasser

  Impressum  